The five questions that decide a project
Offer · Acoustic review and commitments
Noise is one of neighbours' first questions, and one of the easiest to make objective. We review the acoustic study, check that it covers night-time, summer and generator testing, and help frame measurable commitments.
You receive:
- a review of the baseline and predictive acoustic study
- weak points: night, full summer load, low frequencies, testing
- commitments to write down: testing hours, post-commissioning measurements
- clear answers for the public meeting
First conversation confidential and with no commitment. Fixed fees proposed in writing before any assignment. Best-efforts obligation.
The problem. A data center runs day and night. What disturbs is not the building but its outdoor equipment, especially at night when background noise drops. An acoustic study done in daytime at partial load reassures wrongly.
WHAT THE RULES SAY
For classified installations under authorisation, the French order of 23 January 1997 limits emergence, the difference between ambient noise with the installation and residual noise without it, in residential areas:
| Ambient noise (installation included) | Day, 7am-10pm | Night, 10pm-7am, Sundays and holidays |
|---|---|---|
| Above 35 and up to 45 dB(A) | 6 dB(A) | 4 dB(A) |
| Above 45 dB(A) | 5 dB(A) | 3 dB(A) |
At the property boundary, the prefectoral order sets levels that in principle cannot exceed 70 dB(A) by day and 60 dB(A) at night. Other regimes have comparable requirements; outside classified installations, public health code rules on neighbourhood noise apply.
WHO IS INVOLVED

Francis Gillard
Data center design & audits
Thirty years in HVAC, twenty in data centers: design, audits and risk analyses up to 30 MW. Read profile →

Blandine Cazelles
Crisis communication & public affairs
Founder of a network of senior crisis management experts, former regional head of communications at La Poste, former Senate chief of staff. Read profile →
HOW IT WORKS
WHAT WE COMMIT TO
Review of connection documents and the announced energisation date for a European data center developer, ahead of its investment decision. Audit of high-voltage equipment sourcing for a petrochemical group.
We do not design, build or sell equipment. No commission, no brokerage. Never on both sides of the same project.
Confidentiality agreement before any document. Professional liability insurance. Best-efforts obligation: only RTE and Enedis commit to capacity and a date.
Source: order of 23 January 1997 on noise emitted by classified installations (AIDA, Ineris), in French. General information: the applicable regime depends on each installation.
FREQUENTLY ASKED QUESTIONS
Is a data center noisy?
The building is not very noisy; its outdoor equipment is more so, especially at night and in summer. It depends on distance to homes and mitigation.